yokogawa tc10 l manual

- Installation of protection and/or safety circuits with respect to a, lightning protector; protective equipment for the system control-, led by the product and the product itself; foolproof or failsafe de-, sign of a process or line using the system controlled by the product, or the product itself; and/or the design and installation of other, protective and safety circuits are to be appropriately implemented, Note: To leave the Configuration session without, - This product is not designed or manufactured to be used in critical, applications that directly affect or threaten human lives. View online (36 pages) or download PDF (3 MB) YOKOGAWA TC10 User manual TC10 PDF manual download and more YOKOGAWA online manuals Also, YOKOGAWA Electric Corporation assumes no liability for the custo-, mer's failure to comply with these requirements. 2.56 in min. Model: TC10-L Quick Guide . Push button for more than 3 seconds, the instrument will come back to the standard display. Yokogawa Electric Corporation for this Product in the EEA. Can I use the DI function to switch between auto/manual and between run stop/start? Brand: digitalview. On burnout, it will be 0 mA. - As a safety measure, always install a circuit breaker (an IEC 60947, compatible product, 5 A, 100 V or 220 V AC) in an easily accessible, location near the instrument. 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, Yokogawa Electric Corporation - TC10 - ENGINEERING MANUAL - PAG. The input resolution specification the TC10 is 30000. A long press allows you to close the conguration parameter procedure (the instrument will come back to the standard display). What settings should I use to output PV transmission from ananalog output terminal on TC10? terminal 1 and 2 to transmitter signal output. (24 VAC/DC), 6.0 VA max. TC10 TEMPERATURE CONTROLLER Engineering Manual Code: IM 05C01E81-02EN Third edition: Feb. 2018 Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns 1. For SSR, mA and V outputs if the line length is longer than 30 m use a shielded wire. The shallow depth of the controller helps to save instrument panel space. A ladder sequence function is included as standard. Wattmeter Instantaneous power is continuously computed, as multiplication of the Load Voltage, Load Current parameter. Enter your email address and check your inbox. Before connecting the output actuators, we recommend to congure the parameters to suit your application (e.g. 2.External components (like zener barriers, etc.) The following symbol is, This manual is an essential part of the product; keep it in a safe place for. Relay output 2,3: 2A, 250 V AC, resistive load. When the maximum front protection (IP65) is. The instrument will show a measured value up to 5% less than SSc value and then it will show an underrange error. The UT75A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. Assign OP4 to the control output operation. Looking for more information on our people, technology and solutions? Note: The group selection is cyclic as well as the selection of the parameters in a group. For supply connections use No. The following general safety precautions must be observed during. Third edition: Feb. 2018. . The TC10 supports easy configuration with codes for quick start-up. The UT32A-D is a compact digital indicating controller with selectable 2-loop control. Search the full list . I selected SP value transmission on TC10, but no SP value is displayed. Select a mounting location having the following characteristics: 2.There is minimum vibrations and no impact; 4.There are no water or other uids (i.e. Only wire the other instruments SG terminal. of use, service life and misuse are not covered by this warranty. The instrument behaviour and its performance are governed by the value of the stored parameters. At this point you can set the operator. The readout is updated every 15 minutes. Brand: YOKOGAWA . The short depth of the controller helps save instrument panel space. The equipment wholly protected by double insulation or, - Whenever a failure or a malfunction of the device may cause dan-, gerous situations for persons, things or animals, please remember, that the plant must be equipped with additional devices which, - We warrant that the products will be free from defects in material. TC10-L is a panel mounting, Class II instrument. View online Manual for YOKOGAWA TC 10-L Controller or simply click Download button to examine the YOKOGAWA TC 10-L guidelines offline on your desktop or laptop computer. Such, applications include nuclear power equipment, devices using, radioactivity, railway facilities, aviation equipment, air navigation. A ladder sequence function is included as standard. TC10. 2.Every change of the SEnS parameter will produces a change of the related parameter and in particular: [11] Ao1L and [12] Ao1H (when the analog retransmission is present) will be forced to the Ex.Range limits. Use a tester or similar device to ensure. If this instrument is used in a manner not specified in this manual. Only wire the other instruments SG terminal. Moreover, provide indication that the. Yokogawa TC10 Temperature Controller Starting at $203.00 Select Options and Add to Cart View Company Reviews Manufactured By Yokogawa Includes FREE Ground Shipping on orders of $1,000 or more FREE Lifetime Tech Support Availability Usually ships in 2-3 weeks Product Manual Product Specs Overview Description Documents Accessories Features {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Floating Production Storage & Offloading (FPSO), Special Solutions of OpreX Transformation, Terminal Logistics Suite VP (Terminal Automation), Visual MESA Supply Chain Scheduling (VM-SCS), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Mobile Field Device Management (FieldMate), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), OpreX Data Model Broker / Design Data Validation, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Distributed Fiber Optic Temperature Sensor, Industry and Interface Libraries (Applications and Interfaces), Yokogawa Pre-Engineered Analyzer Solutions - YES, Loading, Metering and Blending Automation, Plant Annunciator and SOE Recording System, Transmitterless SENCOMSMART Sensor Platform, Advanced Control Bioreactor System BR1000, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, Support Information - New Legislative Framework (NLF) Conforming Products, Temperature Control for Seal-heating Parts in Wrapping Machinery. There is minimum vibrations and no impact; 4. exposed terminals and wiring on the back. The relative humidity is in accordance with the instrument, The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - Digital Input (DI2) connecting a free of. 1 to 4 indicate the status of outputs 1 to 4. The short depth of the controller helps save instrument panel space. RS-485 interface allows to connect up to 30 devices with one remote master unit. Do not short-circuit the terminals of the SSR output. The UT32A-V,-C,-R is an easily configurable single-loop controller for 1/8 DIN sized. values and the controller output instantaneous value. OUTLINE DIMENSIONS (mm) 1.1 INSTRUMENT DIMENSIONS 48 PV Optional gasket 1.2 PANEL CUT-OUT 45 +0.6 mm 1.78 +0.023 When a shielded cable is used, it should be connected at, 4. There are no water or other fluids (i.e. Fsc allows the scaling of the analog input to set the maximum displayed/measured value. SSR outputs are not isolated. NOTE: This parameter will be shown only when a TC or RTD input has been selected. ]inP Group - Main and auxiliary input conguration. Installation altitude: less than 2000 m; The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. Note: Before starting the configuration code setting, please define and write down Cod1 and Cod2 as needed: Linear 0 to 20 mA (this selection forces Out 4 = TX), Linear 4 to 20 mA (this selection forces Out 4 = TX), Note: As default, when the alarms are active, only AL1 threshold, is available at "Operator Command" level to perform non, critical tasks. Can I hide the SP display? Fr 8am to 5pm ET, The Yokogawa TC10-L Temperature Controller is recommended replacement. The EU Declaration of Conformity and the manual of the controller. Input impedance: > 1 MW for mV Input 500 kW for Volt Input. The UT55A/UT52A also support open networks such as Ethernet communication. -For supply connections use No. All information about the controller use can be found in the Engineering Manual: - IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN and General Specification: GS 05C01E81-01EN. The ambient temperature is in accordance with the operative, 6. In other words the upper display will show: ]INP. and workmanship for 18 months from the date of manufacturing. When the upper display is showing a parameter and, Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. Every group denes all parameters related with a specic function (e.g. Can't find your region? - For control relay output, alarm relay output, and power terminal, L H C o R o D o F /GK Temperature Controller, NOTE about the structure of this document, The usual installation sequence is the reverse of the operator, During installation, the first step is the wiring procedure followed, by the complete configuration. Is there a controller to which I can connect a 2-wire Pt1000 sensor? There is minimum vibrations and no impact; 4. Yokogawa Electric Corporation for this Product in the EEA. The shallow depth of the controller helps to save instrument panel space. I want to use the detailed parameter setting method of TC10, but what number is the password? Click here to select options, We're open Mo-Th 8am to 5:30pm. A short press allows to exit from the current parameter group and select a new parameter group. Note: During the test, the instrument continues to operate at the measurement accuracy within specication. These meters commonly measure voltage, resistance, continuity, capacitance, and more. 1, This instrument is intended for permanent installation, for, indoor use only, in an electrical panel which encloses the. The. desired, the optional gasket must be mounted. can be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Yokogawa Europe BV (Address: Euroweg 2 , 3825 HD Amersfoort, The Netherlands) is the Authorised Representative of. Copyright 1994-2023 Yokogawa Electric Corporation. 2. It has been de- signed with compliance to the European Directives. Looking for more information on our people, technology and solutions? There is minimum vibrations and no impact; There are no water or other uids (i.e. - This product is intended to be handled by skilled/trained person-, - This instrument is for Measurement Category No. The following symbol is, This manual is an essential part of the product; keep it in a safe place for. View and Download Yokogawa UT55A instruction manual online. - Modification of the product is strictly prohibited. requirements of the area in which the instrument is being installed. 1. The SP value is not displayed if you dont specify a control operation. Digital indicating controllers (476 pages), Program temperature controller (37 pages), Temperature measurement module (44 pages), Manual will be automatically added to "My Manuals", Temperature Controller YOKOGAWA TC10 Engineering Manual, Temperature Controller Yokogawa TC10 Quick Manual, Temperature Controller YOKOGAWA TC User Manual, Temperature Controller YOKOGAWA UT55A User Manual, Temperature Controller YOKOGAWA UP150 User Manual, Temperature Controller YOKOGAWA XS550 User Manual, Temperature Controller YOKOGAWA UT130 Technical Information, Temperature Controller YOKOGAWA UT150 User Manual, Temperature Controller YOKOGAWA UT100 Series User Manual. Input impedance:> 1 M. can be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Yokogawa Europe BV (Address: Euroweg 2 , 3825 HD Amersfoort, The Netherlands) is the Authorised Representative of. What is the measured current of the TC10's RTD input? - Do not short-circuit the terminals of the SSR output. "), 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns. Note: This filter will affect the measured value but also the control action the analogue retransmission and the alarms, Overall dimensions (L x H x D): 48 x 48 x 73 mm, This instrument is intended for permanent installation, for indoor. terminal 1 and 2 to transmitter signal output. Code: IM 05C01E81-02EN. (100 to 240 VAC); Insulation voltage: 2300 V rms according to EN 61010-1; Total Accuracy: 0.5% F.S.V. What is the I/O response time of the TC10? Can I use the DI function to switch between auto/manual and between run stop/start? 2. The UT55A and UT52A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. 2. suit your application (e.g. The. All information about the controller use can be found in the Engineering Manual: IM 05C01E81-12EN and the Communication Manual: IM 05C01E81-13EN and General Specification: GS 05C01E81-11EN. The upper display will show PASS while the lower display shows 0; 2.Using and buttons set the value -481; 4.The instrument will turn OFF all LEDs for a few seconds, then the upper display will show dFLt (default) and then all LEDs are turned ON for 2 seconds. - Install the power cable keeping a distance of more than 1 cm from, - The power cable is required to meet the IEC standards concerned or the. This is a list of recorder and controller products that support the New Legislative Framework (NLF.). user must refer to the Engineering manual for special instructions. YOKOGAWA Manuals and User Guides All-Guides Database contains 857 YOKOGAWA Manuals (1264 Devices) for Free Downloading (PDF). Also, YOKOGAWA Electric Corporation assumes no liability for the customer's, failure to comply with these requirements. Do I need a minus sign ( - ) on the alarm setting value? The conguration procedure allows to take advantage of all instrument features. IM 05C01E81-11EN, 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, EU Declaration of conformity and Manual retrieval, TC10-L is a panel mounting, Class II instrument. However, the instrument will only show the parameters applicable to its hardware options in accordance with the specic instrument conguration (i.e. The shallow depth of the controller helps to save instrument panel space. Search the full list . External components (like zener barriers, etc.) 16 AWG or larger wires rated for at last 75C. For measurements performed in the building instal-, For measurements performed at the source of the, - Wiring work must be carried out by a person with basic electrical, - Be sure to turn OFF the power supply to the controller before wiring, to avoid an electric shock. For measurements performed in the building, For measurements performed at the source of, - Wiring work must be carried out by a person with basic electrical, - Be sure to turn OFF the power supply to the controller before wiring, to avoid an electric shock. [34] r.md equal to 1(Limit output is de-energized at power on in any cases. exposed terminals and wiring on the back. The access to the conguration parameters is protected by a password. Pages: 30 . [13] AL1 and [30] AL2 will be forced to : for an absolute maximum alarm, them will be forced to the maximum input span, for an absolute minimum alarm, them will be forced to the minimum input span, for all other alarm, them will be forced to zero, [14] HAL1 and [31] HAL2 will be forced equal to the 0.5% of the input span, [35] HYS will be forced equal to 0.05 % of the input span, the CAL group will be reset [51]A.L.P, [52] A.L.O, [53] A.H.P, [54] A.H.O. Case: Plastic, self-extinguishing degree: V-0 according to UL 94; Front protection: IP 65 (when the optional panel gasket is mounted) for indoor locations according to EN 60070-1; Terminals protection: IP 20 according to EN 60070-1; Terminal block: 16 screw terminals for cables of. terminal 1 and 2 to transmitter signal output. 4. For complete controller configuration see the Engineering Manual. When using an external power supply with 2-wire wiring of TC10, what is the input resistance when inputting 4-20 mA? We assume no liability for safety, or responsibility for, the product's quality, performance or functionality should users. A ladder sequence function is included as standard. External resistance: 100W max., maximum error 25 V. Cold junction: automatic compensation between 0 to 55C. Notes: 1. IP65 rated as "dust tight" and protected against water projected from a nozzle when the optional panel gasket is mounted (for indoor locations) according to EN 60070-1. Every change of the SEnS parameter will produces a change of the related parameter and in particular: [11] Ao1L and [12] Ao1H (when the analog retransmission is present) will be forced to the Ex.Range limits. - Wiring should be installed to conform to NEC (National Electrical, Code: ANSI/NFPA-70) or the wiring construction standards in. This manual is intended for the following personnel: - Engineers responsible for installation, wiring, and maintenance of, - Personnel responsible for normal daily operation of the, Calls attention to actions or conditions that could cause serious or, fatal injury to the user or damage to the instrument, and indicates, precautions that should be taken to prevent such occurrences. observe these instructions when operating the product. The ambient temperature is in accordance with the operative, 6. The short depth of the controller helps save instrument panel space. If so used, it is the user's responsibility to include in the system additional. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. all phases of operation, service and repair of this instrument. The UT75A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. If so used, it is the user's responsibility to include in the system additional. Download this manual TEMPERATURE CONTROLLER Model: TC10 - Quick Guide . Yokogawa Electric Corporation - TC10 - ENGINEERING MANUAL - PAG. The Yokogawa TC10 is a compact,all-in-one, single loop temperature controller with an easy-to-read, 3-color LED display. Looking for more information on our people, technology and solutions? requirements of the area in which the instrument is being installed. I want to use it as a display. On the TC10, what does it mean if AL and 1 are lit? 600W. With thermocouple K input, can I display digits after the decimal point for the temperature? Sometime, e.g. If this instrument is used in a manner not specified in this manual. The UT55A and UT52A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. Model: TC10 - Quick Guide . The Yokogawa TC10-L is an all-in-one, FM approved limit controller with an easy-to-read, 3-color LED display. AL on the front of the TC10 is the alarm lamp. The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. The ambient temperature is in accordance with the operative, 6. displayed value becomes 999.9C or 999.9F. TC10-Ls compact design allows for a broad range of applications/uses while maintaining a high level of accuracy. 0.25 to 2.5 mm2 (AWG22 to AWG14) with connection diagram, tightening torque 0.5 Nm; Dimensions: 48 x 48, depth 73 mm, (1.89 x 1.89 x 2.87 in. The UT32A-V,-C,-R is an easily configurable single-loop controller for 1/8 DIN sized. View online (2 pages) or download PDF (1 MB) YOKOGAWA TC10 User manual TC10 measuring, testing & control PDF manual download and more YOKOGAWA online manuals Notes: 1. Features 3 Dynamic Colors Led Display Compact size: 48 x 48 mm (1/16 DIN), depth 48 mm Download Instructions manual of digitalview ALR-1400 Controller for Free or View it Online on All-Guides.com. Note: For TC and RTD inputs the decimal figure must be 0 or 1 only. Products and components that are subject to wear due to conditions. (100 to 240 VAC), Insulation voltage: 2300 V rms according to EN 61010-1, Front protection: IP 65 (when the optional panel gasket is mounted), Accessories: Mounting bracket, Quick Guide, Operative Modes: Auto / Manual / Stand-by (force control output to zero), Serial Communication (optional): RS-485 MODBUS, PID control with single or double action with overshoot control (Fuzzy overshoot control), ON/OFF, ON/OFF Neutral Zone, Auto-tuning, and Self-tuning. Id like to confirm the parameters that can be set for TC10 RS485 communication setting criteria (protocol, baud rate, parity, stop bit, data length).

Poseidon Redwood Bike, Rasta Festival Clothing, Chickasaw Senior Community Franklin, Tn, Michael Gardner Dentist, Illinois State University Honors Scholarship, Articles Y